cantera/test_problems/silane_equil/output_blessed.txt
Ray Speth 1c09f7f14b [Thermo] Make continuity check for enthalpy dimensionally consistent
All quantities here are nondimensional, so taking h+cp*T makes no sense, and
caused the test to pass even for suspicously discontinuous thermo data (although
the bad data would generally get flagged by the tests for cp and/or s).
2015-12-15 11:41:54 -05:00

36 lines
1.2 KiB
Text

**** WARNING ****
For species SI2H6, discontinuity in h/RT detected at Tmid = 1000
Value computed using low-temperature polynomial: 19.8328
Value computed using high-temperature polynomial: 19.9055
**** WARNING ****
For species SI2H6, discontinuity in s/R detected at Tmid = 1000
Value computed using low-temperature polynomial: 49.5493
Value computed using high-temperature polynomial: 49.7214
**** WARNING ****
For species SI3H8, discontinuity in h/RT detected at Tmid = 1000
Value computed using low-temperature polynomial: 29.3028
Value computed using high-temperature polynomial: 29.4297
**** WARNING ****
For species SI3H8, discontinuity in s/R detected at Tmid = 1000
Value computed using low-temperature polynomial: 65.9731
Value computed using high-temperature polynomial: 66.2781
**** WARNING ****
For species SI2, discontinuity in h/RT detected at Tmid = 1000
Value computed using low-temperature polynomial: 74.0115
Value computed using high-temperature polynomial: 74.0387
**** WARNING ****
For species SI2, discontinuity in s/R detected at Tmid = 1000
Value computed using low-temperature polynomial: 32.8813
Value computed using high-temperature polynomial: 32.9489