Fixing unit conversion of tabulated data in BinarySolutionTabulatedThermo
Previously the model imported the tabulated data assuming it was given in J, mol, K units, and ignoring any user input in the cti file, w/r/t units. This fixes that, by amending the `getFloatArray` calls in thermo/BinarySolutionTabulatedThermo.cpp
This commit is contained in:
parent
366d1942ef
commit
11271d90b2
1 changed files with 5 additions and 5 deletions
|
|
@ -53,7 +53,7 @@ void BinarySolutionTabulatedThermo::_updateThermo()
|
|||
if (m_tlast != tnow || m_xlast != xnow) {
|
||||
c[0] = tnow;
|
||||
d = interpolate(xnow);
|
||||
c[1] = d[0] * 1e3; // 1e3 for conversion J/mol -> J/kmol
|
||||
c[1] = d[0];
|
||||
if (xnow == 0)
|
||||
{
|
||||
dS_corr = -BigNumber;
|
||||
|
|
@ -64,7 +64,7 @@ void BinarySolutionTabulatedThermo::_updateThermo()
|
|||
{
|
||||
dS_corr = GasConstant*std::log(xnow/(1.0-xnow)) + GasConstant/Faraday*std::log(this->standardConcentration(1-m_kk_tab)/this->standardConcentration(m_kk_tab));
|
||||
}
|
||||
c[2] = d[1] * 1e3 + dS_corr; // 1e3 for conversion J/K/mol -> J/K/kmol
|
||||
c[2] = d[1] + dS_corr;
|
||||
|
||||
c[3] = 0.0;
|
||||
type = m_spthermo.reportType(m_kk_tab);
|
||||
|
|
@ -120,9 +120,9 @@ void BinarySolutionTabulatedThermo::initThermoXML(XML_Node& phaseNode, const std
|
|||
}
|
||||
if (thermoNode.hasChild("tabulatedThermo")) {
|
||||
XML_Node& dataNode = thermoNode.child("tabulatedThermo");
|
||||
getFloatArray(dataNode, x, false, "", "moleFraction");
|
||||
getFloatArray(dataNode, h, false, "", "enthalpy");
|
||||
getFloatArray(dataNode, s, false, "", "entropy");
|
||||
getFloatArray(dataNode, x, true, "", "moleFraction");
|
||||
getFloatArray(dataNode, h, true, "J/kmol", "enthalpy");
|
||||
getFloatArray(dataNode, s, true, "J/kmol/K", "entropy");
|
||||
|
||||
// Check for data length consistency
|
||||
if ((x.size() != h.size()) || (x.size() != s.size()) || (h.size() != s.size())) {
|
||||
|
|
|
|||