Commit graph

9 commits

Author SHA1 Message Date
Henry Weller
7bdbab7f4e Rationalize the "pos" function
"pos" now returns 1 if the argument is greater than 0, otherwise it returns 0.
This is consistent with the common mathematical definition of the "pos" function:

https://en.wikipedia.org/wiki/Sign_(mathematics)

However the previous implementation in which 1 was also returned for a 0
argument is useful in many situations so the "pos0" has been added which returns
1 if the argument is greater or equal to 0.  Additionally the "neg0" has been
added which returns 1 if if the argument is less than or equal to 0.
2017-06-22 14:32:18 +01:00
Henry Weller
08165a9c1e Documentation updates
Patch contributed by Bruno Santos
Resolves patch request https://bugs.openfoam.org/view.php?id=2409
2016-12-27 14:35:39 +00:00
Henry Weller
4603a8b253 fvPatchFields: Constructors from dictionary now call the corresponding constructor of the fvPatchField base-class
to ensure 'patchType' is set as specified.

Required substantial change to the organization of the reading of the
'value' entry requiring careful testing and there may be some residual
issues remaining.  Please report any problems with the reading and
initialization of patch fields.

Resolves bug-report http://bugs.openfoam.org/view.php?id=2266
2016-09-25 09:11:53 +01:00
Henry Weller
9f67acdc53 Updated header documentation processed by Doxygen 2016-06-19 21:23:54 +01:00
Henry Weller
8a5304edf6 Doxygen documentation: Standardized the 'See also' heading 2016-06-17 17:31:34 +01:00
Henry Weller
2ca0a6f362 Doxygen documentation: Use the standard 'Usage' rather than the '\heading....' 2016-06-17 17:22:24 +01:00
Henry Weller
2c6b405043 fireFoam: Added optional hydrostatic initialization of the pressure and density
Also added the new prghTotalHydrostaticPressure p_rgh BC which uses the
hydrostatic pressure field as the reference state for the far-field
which provides much more accurate entrainment is large open domains
typical of many fire simulations.

The hydrostatic field solution is controlled by the optional entries in
the fvSolution.PIMPLE dictionary, e.g.

    hydrostaticInitialization yes;
    nHydrostaticCorrectors 5;

and the solver must also be specified for the hydrostatic p_rgh field
ph_rgh e.g.

    ph_rgh
    {
        $p_rgh;
    }

Suitable boundary conditions for ph_rgh cannot always be derived from
those for p_rgh and so the ph_rgh is read to provide them.

To avoid accuracy issues with IO, restart and post-processing the p_rgh
and ph_rgh the option to specify a suitable reference pressure is
provided via the optional pRef file in the constant directory, e.g.

    dimensions      [1 -1 -2 0 0 0 0];
    value           101325;

which is used in the relationship between p_rgh and p:

    p = p_rgh + rho*gh + pRef;

Note that if pRef is specified all pressure BC specifications in the
p_rgh and ph_rgh files are relative to the reference to avoid round-off
errors.

For examples of suitable BCs for p_rgh and ph_rgh for a range of
fireFoam cases please study the tutorials in
tutorials/combustion/fireFoam/les which have all been updated.

Henry G. Weller
CFD Direct Ltd.
2016-04-23 10:04:39 +01:00
Henry Weller
ad529cf414 prghPressureFvPatchScalarField: Updated documentation
Corrected rho name specification.
Resolves bug-report http://openfoam.org/mantisbt/view.php?id=1956
2015-12-17 12:20:10 +00:00
Henry Weller
033e73e3f9 prghTotalPressureFvPatchScalarField: Total pressure BC for p_rgh
Resolves some stability issues with the outlet of multiphase problems.
2015-10-14 13:15:17 +01:00